View History

Your Position:Home > TEST AND MEASURING INSTRUMENT > Clamp Meter > 360 Leakage Current Clamp Meter Fluke

360 Leakage Current Clamp Meter Fluke

上一个商品 下一个商品
    • NO.:360
    • Brand:Fluke
    • Weight:0gram
    • Sales time:2014-12-08
    • Goods click count:372
    • Rank: comment rank 5
    • Shop price:RM3381.00
    • 注册用户:RM3381.00
    • Quantity:
    • Total: [ Other Currencies ]

Goods Description

Attribute

Goods Tag

Accessories Releate

 deally designed for non-invasive checks of insulation condition, the Fluke 360 leakage meter allows you to perform tests without powering down the installation or disconnecting equipment - saving you time, without compromising on quality or safety. 

The unique jaw design of the Fluke 360 AC Leakage Current Clamp Meter eliminates the influence of adjacent current conductors, and minimizes the effects of external magnetic fields, even at low currents. This allows you to perform accurate and reliable tests in today’s crowded electrical environments. The tough and high-quality jaw design of the Fluke 360 leakage tester guarantees high stability for long-term repeatability and durability.

Why leakage current testing?
Leakage currents can be an indicator of the effectiveness of insulation on conductors. High levels of leakage current may be present in circuits where either the insulation resistance is low, or electronic equipment with filters is used. Leakage currents can cause disruptions of the normal operation of equipment and installations. It is possible to locate the source of leakage currents by using the Fluke 360 leakage current clamp meter and taking methodical measurements throughout the installation. The big advantage of leakage current testing versus insulation testing is that the installation and equipment do not need to be powered down but can be done during normal operation.

 

Features and benefits of the Fluke 360

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

 

General Specifications

Method of detection

 

 Mean value

 

Display

Digital display:

 3200 counts

Bar-graph display:

 32 segments, LCD

 

Measurement Cycle

 

 2 times/second (Digital display), 12 times/second (Bar-graph display)

 

Range switching

 

 Auto-range

 

Ambient temperature and humidity

 

 0 °C to 50 °C, 80 % RH or less (no condensation)

 

Temperature coefficient

 

 0.05% of range/°C or less (within the ranges of 0 °C to 18 °C and 28 °C to 50 °C for measurement of 0-50 A)

 

Influence of external magnetic field

 

 0.0005% typical

 

Influence of conductor position

 

 Within accuracy

 

Circuit voltage

 

 <300 Vrms

 

Safety standard

 

 EN 61010-1, EN 61010-2-032, 300 V CAT III, Pollution Degree 2

 

Withstanding voltage

 

 3.7 kV ac

 

Battery type

 

 1 x 3 V Lithium battery (button cell) CR2032

 

Battery life

 

 Approx. 90 hours (when continuously used)

 

Auto power-off

 

 Approx. 10 minutes

 

Diameter of measurable conductor

 

 40 mm max.

 

Weight

 

 200 g

 

Dimension

 

 176 mm x 70 mm x 25 mm

 

Operating altitude

 

 2000 m

 

 

Electrical Specification

Specifications at

 

 23 ± 5 ºC, 80 % RH max

 

Accuracy

 

 (% readout + value of least significant digit)

 

3 mA

 

 Resolution: 0.001 mA
Accuracy: 1% + 5
Max Permissible current: 60 A rms

 

30 mA

 

 Resolution: 0.01 mA
Accuracy: 1% + 5
Max Permissible current: 60 A rms

 

30 A

 

 Resolution: 0.01 A
Accuracy: 1% + 5
Max Permissible current: 60 A rms

 

60 A

 

 Resolution: 0.1 A
Accuracy: 5% + 5 
Max Permissible current: 60 A rms

 

Mean value detection and rms-value calibration

Accuracy specified at:

 50/60 Hz

 

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages. First Prev Next Last

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha
© 2005-2017 MTIS Electrical Supply Malaysia www.electricals.com.my Copyright, All Rights Reserved. 18, Jalan Bayu Tinggi 6, Taman Bayu Tinggi , 41200 Klang, Selangor Darul Ehsan. E-mail: sales@mtis.com.my
Skypewww.mtis.com.my
Run 81 queries, spents 0.051203 seconds, 84 people online,Gzip enabled,take up memory 6.127 MB
shopify traffic stats
rss