View History

Your Position:Home > TEST AND MEASURING INSTRUMENT > Clamp Meter > 1630 Earth Ground Clamp Meter Fluke

1630 Earth Ground Clamp Meter Fluke

上一个商品 下一个商品
    • NO.:1630
    • Brand:Fluke
    • Weight:0gram
    • Sales time:2014-12-08
    • Goods click count:453
    • Rank: comment rank 5
    • Shop price:RM9950.00
    • 注册用户:RM9950.00
    • Quantity:
    • Total: [ Other Currencies ]

Goods Description

Attribute

Goods Tag

Accessories Releate

 Fluke 1630 Features :

Earth Ground loop resistance measurements for commercial, industrial, and utility applications

The clamp-on ground testing technique used by the Fluke 1630 simplifies ground loop testing and enables non-intrusive leakage current measurement. The compact and rugged design makes the Fluke 1630 easy to use in small places and harsh environments, while the ‘display hold’ and the continuity testing with an audible alarm function ensures convenience in use. The novel technique means that earth ground loop testing and continuity testing can be completed without breaking the circuit.

Stakeless testing system
The Fluke 1630 uses the Stakeless testing method, which eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons. With the Stakeless testing method, earth ground stakes are no longer necessary. The Fluke 1630 Earth Ground Clamp is placed around the earth ground rod or the connecting cable. A known voltage is induced by one half of the clamp and the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection.

 

·         A wide ground loop resistance range, from 0.025 Ω to1500 Ω, to satisfy all requirements

·         Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars

·         Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshooting

·         Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications

·         User-defined HI / LO Alarm limits, for rapid measurement evaluation

·         Handy ‘display hold’ button for capturing readings in hard-to-reach places

·         Time saving memory function automatically records and stores measured values

·         Automatic self calibration ensures correct measurement every time

·         Overload protection: 200 A

·         Carrying case and resistance test loop included

·         ≥ 8 hours battery life (continuous operation)

 

 

Fluke 1630 Specification :

Operating error

 

 Refers to the operating temperature range and is guaranteed for 2 years

Storage temp. range

 

 -20 °C to 60 °C (-4°F to 140 °F)

Reference temp. range

 

 23 °C ± 5 °C (73 °F ± 9 °F)

Storage humidity

 

 <75 % Rh

Operating humidity

 

 <85% Rh

Display

 

 999 digital LC display with special symbols

Protection

 

 IP30 according to IEC 529/EN 60529

Safety

 

 300 V, CAT III pollution degree 2 IEC 61010-1 and IEC 61010-2-032

Weight

 

 750 g (1.165 lbs)

Conductor size

 

 35 mm (1.38 in) approximately

Dimension (length x width x depth)

 

 276 mm x 100 mm x 47 mm (10.8 in x 3.9 in x 1.9 in)

Emission

 

 IEC 1000 4-2, IEC 61326-I class B

Immunity

 

 IEC 61000-4-2, 8 kV (air) criteria A

 

 IEC 61000-4-3, 3 V/m performance criteria A

Range selection

 

 Auto

Overload indicator

 

 "OL" on display

Measuring time

 

 0.5 sec

Measuring frequency

 

 3.333 kHz

Battery type

 

 9 V alkaline (type IEC 6 LR 61)

Battery life

 

 ≥ 8 hours (continuous operation)

Power consumption

 

 40 mA

Low battery indication

 

 Display symbol

 

Ground Loop Resistance (Autorange)

Range

 

 Accuracy
(± % of reading Ω)

0.025 - 0.250 Ω

 

 ± 1.5 % rdg ± 0.02 Ω

0.250 - 9.999 Ω

 

 ± 1.5 % rdg ± 0.05 Ω

10.00 - 99.99 Ω

 

 ± 2.0 % rdg ± 0.3 Ω

100.0 - 199.9 Ω

 

 ± 3.0 % rdg ± 1.0 Ω

200.0 - 400.0 Ω

 

 ± 5.0 % rdg ± 5 Ω

400.0 - 600.0 Ω

 

 ± 10 % rdg ± 10 Ω

600.0 - 1500 Ω

 

 ± 20 %

Note:

 

 Loop resistance with no inductance, external magnetic field < 50A/m, external electrical field < 1 V/m, conductor centered.

 

 

 

 

 

 

 

 

 

 

Fluke 1630 Included Accessories

·         Rugged carrying case with shoulder strap

·         Resistance test loop

·         9 V battery

·         User's manual in English, French, Spanish, German, Italian, Portuguese, and Simplified Chinese

 

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages. First Prev Next Last

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha
© 2005-2018 MTIS Electrical Supply Malaysia www.electricals.com.my Copyright, All Rights Reserved. 18, Jalan Bayu Tinggi 6, Taman Bayu Tinggi , 41200 Klang, Selangor Darul Ehsan. E-mail: sales@mtis.com.my
Skypewww.mtis.com.my
Run 81 queries, spents 0.050878 seconds, 265 people online,Gzip enabled,take up memory 6.118 MB
shopify traffic stats
rss